Diagnostic opportunities in dysfunction of heart valve prosthesis (literature review)

D.V. Shatov, E.A. Zakharyan

Abstract


The article describes the diagnostic methods inten­ded to detect dysfunction of the implanted heart valve mechanical prostheses. The symptoms revealed by electrocardiography, radiography, cine-fluoroscopy, transthoracic and esophageal echocardiography, multidetector computed tomography are demonstrated. The comparative characteristic allowing differentiating a pannus from thrombosis of prosthesis is given. The citation bases PubMed, RSCI, Scopus, Web of Science, Google Scholar were used for full disclosure of the topic of the review article, with the presentation of modern views on the study of this problem.

Keywords


thrombosis of the prosthesis; pannus; diagnosis; electrocardiography; radiography; echocardiography; computed tomography

References


Зорина И.Г., Назаров В.М. Неинвазивная оценка функции искусственных клапанов сердца // Патология крово­обращения и кардиохирургия. — 2002. — № 2. — С. 4-6.

Zoghbi W.A., Chambers J.B., Dumesnil J.G., Foster E. et al. Recommendations for evaluation of prosthetic valves with echocardiography and doppler ultrasound // J. Am. Soc. Echocardiogr. — 2009. — Vol. 22. — P. 975-1014. DOI: 10.1016/j.echo.2009.07.013.

Nishimura R.A., Otto C.M., Bonow R.O., Carabello B.A. et al. 2014 AHA/ACC Guideline for the Management of Patients with Valvular Heart Disease // Journal of the American College of Cardiology. — 2014. — Vol. 63, № 22. — P. e57-185. DOI: 10.1016/j.jacc.2014.02.536.

Jong Hyun Choi, Jung Hyun Choi, Seunghwan Song, Myung-Yong Lee. Intermittent, Non Cyclic Severe Mechanical Aortic Valve Regurgitation // J. Cardiovasc. Ultrasound. — 2013. — Vol. 21, № 4. — P. 189-191. DOI: 10.4250/jcu.2013.21.4.189.

Salamon J., Munoz­Mendoza J., Liebelt J.J., Taub C.C. Mechanical valve obstruction: Review of diagnostic and treatment strategies // World J. Cardiol. — 2015. — Vol. 7, № 12. — P. 875-881. DOI: 10.4330/wjc.v7.i12.875.

Kassi M., Garg N., Chang S.M. utility of cardiac computed tomography for assessment of prosthetic aortic valve dysfunction with pannus formation // Methodist Debakey Cardiovasc J. — 2013. — Vol. 9, № 3. — P. 174-175.

Gündüza S., Özkana M., Bitekera M., Güneysub T. Ima­ging of the mechanical heart valve pannus formation with multidetector computerised tomography // Eur. J. Cardiothorac. Surg. — 2010. — Vol. 37, № 6. — P. 172-175. DOI: 10.1016/j.ejcts.2010.01.013.

Gündüz S., Özkan M., Kalçik M., Gürsoy O.M. Sixty-Four-Section Cardiac Computed Tomography in Mechanical Prosthetic Heart Valve Dysfunction Thrombus or Pannus // Circ. Cardiovasc. Imaging. — 2015. — Vol. 8, № 12. — P. e003246. DOI: 10.1161/CIRCIMAGING.115.003246.

Ueda T., Teshima H., Fukunaga Sh., Aoyagi Sh., Tanaka H. Evaluation of Prosthetic Valve Obstruction on Electrocardiographically Gated Multidetector-Row Computed Tomo­graphy — Identification of Subprosthetic Pannus in the Aortic Position // Circulation Journal. — 2013. — Vol. 77. — P. 419-423. DOI: 10.1253/circj.CJ-12-0290.

Tanis W., Budde R.P.J.,Van der Bilt I.A.C., Delemarre B. et al. Novel imaging strategies for the detection of prosthetic heart valve obstruction and endocarditis // Neth. Heart J. — 2016. — Vol. 24. — P. 96-107. DOI: 10.1007/s12471-015-0796-0.

Moldovan M.-S., Bedeleanu D., Kovacs E., Ciumărnean L., Molnar A. Pannus-related prosthetic valve dysfunction. Case report // Clujul Medical. — 2016. — Vol. 89, № 1. — P. 169-175. DOI: 10.15386/cjmed-510.




Copyright (c) 2018 EMERGENCY MEDICINE

Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 International License.

 

© Publishing House Zaslavsky, 1997-2018

 

   Seo анализ сайта